Da Vinci Medical

VO2 Pro™ Bagless EWOT System

$13,695.00 Sold out

World’s first bagless EWOT system delivering unlimited oxygen.
No Bag. No Waiting. No Limits.

VO2 Pro delivers unlimited flow of high-purity O2 without the wait time of traditional bag systems. This patent pending technology overcomes the bottleneck of time to refill between session in a commercial setting and takes up less space than any system in the world at under 3 square feet.

Already have an oxygen generator for EWOT?
Check out our HyperMax EWOT System

Important note: You are pre-ordering a product in full, which will ship in 2-3 weeks.

This product is sold out. Join our waitlist by calling or contacting us.

Oxygen Mask Size: X Small
Mask Sizing Guide
Choose Your Product Options:
Choose Region *
Painting Format *
Image Resolution *
Frame
Portrait Canvas Size (With Frame) *
Add HQ Digital Image
Mint as NFT
Contact us
Specifications

Weight: 155 lbs
Size: 30" x 13.5" x 30 (occupies 2.8 sq ft)
Timer: Auto shutoff timer @ 5 min increments
Noise Level: 70dB
Generator Flow Rate: 70LPM
O2 Purity: Max 50%, Min 40%
Inspiratory Capacity: No limit (represents how many liters per minute a user can breathe)
Power Requirements: 110V/15 AMP. Draws 11 AMPS.
Filter: 2x HEPA + Medical Filter 

What Is Included
  • 70 lpm generator
  • VO2 pro server
  • 1 10' oxygen hose
  • 1 oxygen mask
  • Oxygen hose & mask hook for storage
  • Remote Control
  • 4 spare hepa pre-filters
  • 2 medical filters (1 spare)
  • 3 3/8" od silicone feed hoses (1 spare)
  • 1 user manual for each device
Tax and Financing
Shipping

Free Shipping within the US.

Important note: You are pre-ordering a product in full that will ship in 2-3 weeks.

Warranty

Warranty: 2 years

International Customers

International customers: to ensure a seamless and personalized ordering experience, we kindly ask that you place your orders through a direct call with our team. This allows us to cater to your specific needs, including shipping preferences and any inquiries you may have about our products. We’re excited to serve you globally!

+1-888-391-5350

Disclaimer

System exhausts high-flow warm air during usage. Use in a well cooled room with ventilation. System includes 4" output port to vent warm air (optional). Port is built-in and vent hose can be attached if desired. 


Expectant mothers should consult a healthcare professional before using biohacking technologies.

NO BAG. NO WAITING. NO LIMITS. 

Our OptiFlow™ feature allows for a user to breathe at any LPM (liters per minute) as the system will introduce room air to cover the demand during sprints. This lowers the purity by a variable percentage based on demand. The system will never drop below 40% purity during this time as traditional EWOT only requires 40% purity. Simply set the timer to operate at 5 minute increments and VO2 Pro shuts off automatically. 

Unmatched Oxygen Purity

Our VO2 Pro System delivers the cleanest oxygen available, passing through dual HEPA filters and a high-flow medical-grade filter before reaching the oxygen hose. Experience the highest standard in oxygen filtration on the market.

Don't believe the hype of needing 93+% O2 Purity

All oxygen generators make this purity so that became the "story" all competitors use and has no scientific backing. ZERO. Refer to the original clinical studies that spawned EWOT, supporting the use of only 40% purity in Manfred von Ardenne's Oxygen Multi-step Therapy: Physiological and Technical Foundations.

  • Auto shutoff at any duration (5 min increments)
  • Occupies under 3 sq ft.
  • Instant high-flow
  • Accommodates any LPM demand

Learn More about O2 Purity

Why 50% Oxygen? It’s the Sweet Spot for Utilization

During exercise, the body’s ability to use oxygen is driven more by circulatory efficiency, mitochondrial capacity, and capillary perfusion, rather than simply increasing the oxygen percentage in the air you breathe.


Multiple studies have demonstrated that:

  • Hemoglobin saturation approaches 98–100% at oxygen concentrations as low as 30–40%.
  • Once hemoglobin is fully saturated, any additional oxygen (above ~40–50%) dissolves in plasma and provides limited additional benefit to cellular uptake.
  • The body is not oxygen-limited above this point — it’s delivery- and utilization-limited.

In other words, increasing FiO₂ beyond 50% may sound more powerful, but oxygen uptake plateaus and performance returns diminish beyond that threshold.

Scientific Backing:

Wagner et al. (2006) and Richard Bloomer (2009) confirmed that oxygen delivery and VO₂ max do not significantly increase when FiO₂ rises above 50% during exercise.

The body simply can’t absorb or use much more oxygen once these physiological limits are reached — making 50% the most efficient and optimized range for EWOT.

Is Higher Oxygen Dangerous? Not Necessarily — But Not Always Needed

Our decision to cap the VO2 Pro at 50% purity is not a commentary on safety. Higher oxygen levels, such as 90% FiO₂, have valid applications in clinical or specialized recovery settings. We continue to support and offer systems that deliver higher purity oxygen for users with those specific goals.


However, for active EWOT sessions, where the body is moving, sweating, and circulating blood rapidly, oxygen utilization maxes out well before 90% purity is reached. As such, delivering oxygen at levels beyond 50% doesn’t translate to improved performance or better outcomes — it simply exceeds what the body can use during exercise.

VO2 Pro: Targeted, Efficient, Intelligent Oxygenation

The VO2 Pro is purpose-built for intelligent performance optimization. It delivers:

  • Oxygen purity within the optimal physiological utilization range
  • Consistent oxygen flow to support vascular perfusion and mitochondrial respiration
  • A streamlined, efficient delivery system that enhances usability without compromising results

By focusing on utilization over excess, we ensure users get the most benefit out of every breath, without overengineering a solution the body can’t use. More oxygen isn’t always better — what matters is how much the body can actually use during exercise. The VO2 Pro caps at 50% because that’s where oxygen saturation, performance output, and efficiency peak. We’ve aligned the system with this proven physiological threshold to ensure optimal EWOT outcomes for our users.

Have a question?

Contact our team to speak with a specialist about the VO2 Pro™ Bagless EWOT System.

888-391-5350

Superhuman Protocol

Without magnetism, oxygen and light we cannot survive. With them, we are “Superhuman”. The benefits are compelling no matter if you’re eighty and in a wheelchair or a Gold Medal Olympian. Magnetism, oxygen and light created life.

When you expose the body to these powerful natural forces in the correct order, you can restore it to order.

(Pulsed Electromagnetic Field)

Pulsed electromagnetic induction delivers millions of frequencies per second to restore cellular function. Improves cell voltage and alkalinity. 

(Exercise With Oxygen Training)

Increases pressure in lung and arteries during exercise to assist with oxygen saturation.

(Photobiomodulation)

Red light therapy improves ATP production by reducing competing free radicals blocking O2 transport of mitochondrial cells. 

Superhuman Protocol Packages