Da Vinci Medical
Out Of Stock
VO2 Pro™ Bagless EWOT System
World’s first bagless EWOT system delivering unlimited enriched air.
No Bag. No Waiting. No Limits.
VO2 Pro delivers unlimited flow of enriched air at 54%+- purity without the wait time of traditional bag systems. This patent-pending technology overcomes the bottleneck of time to refill between session in a commercial setting and takes up less space than any system in the world at under 3 square feet.
Already have an oxygen generator for EWOT?
Check out our HyperMax EWOT System
Have a Question?
Specifications
Weight: 155 lbs
Size: 30" L x 13.5" x 26.5" (occupies 2.8 sq ft).
Timer: Auto shutoff timer @ 5 MIN increments.
Noise Level: 70dB
Generator Flow Rate: 60-125LPM
O2 Purity: Min. output 35%. Max output 92%+- (adjustable with a decrease in LPM)
Inspiratory Capacity: NO LIMIT (represents how many liters per minute a user can breathe).
Power Requirements: 110V/15AMP - Draws 11AMPs
Filter: 2x HEPA + Medical Filter
What Is Included
- 70 lpm generator
- VO2 Pro server (top unit)
- 1 10' oxygen hose
- 1 oxygen mask
- Oxygen hose & mask hook for storage
- 2 Medical filters (1 spare)
- 3 3/8" OD silicone feed hoses (1 spare)
- Remote control
- User Manual
Tax and Financing
Shipping
Free Shipping within the US.
Estimated Shipping Time: 2-3 Weeks
Warranty
Warranty: 2 years
International Customers
International customers: to ensure a seamless and personalized ordering experience, we kindly ask that you place your orders through a direct call with our team. This allows us to cater to your specific needs, including shipping preferences and any inquiries you may have about our products. We’re excited to serve you globally!
+1-888-391-5350
Disclaimer
System exhausts high-flow warm air during usage. Use in a well cooled room with ventilation. System includes 4" output port to vent warm air (optional). Port is built-in and vent hose can be attached if desired.
Expectant mothers should consult a healthcare professional before using biohacking technologies.
NO BAG. NO WAITING. NO LIMITS.
Our OptiFlow™ feature allows for a user to breathe at any LPM (liters per minute) as the system will introduce room air to cover the demand during sprints. This lowers the purity by a variable percentage based on demand. The system will never drop below 42% purity during this time as traditional EWOT only requires 40% purity.

Unmatched Oxygen Quality
Our VO2 Pro™ System delivers air passing through dual HEPA filters and a high-flow medical-grade filter before reaching the oxygen hose. Experience the highest standard in oxygen filtration.

Don't believe the hype of needing 93+% O2 Purity
All oxygen generators make this purity so that became the "story" all competitors use and has no scientific backing. ZERO. Refer to the original clinical studies that spawned EWOT, supporting the use of only 40% purity Manfred von Ardenne's Oxygen Multi-step Therapy: Physiological and Technical Foundations.
- Auto shutoff at any duration (5 min increments)
- Occupies under 3 sq ft.
- Instant high-flow
- Accommodates any LPM demand
During exercise, the body’s ability to use oxygen is driven more by circulatory efficiency, mitochondrial capacity, and capillary perfusion, rather than simply increasing the oxygen percentage in the air you breathe.
Multiple studies have demonstrated that:
- Hemoglobin saturation approaches 98–100% at oxygen concentrations as low as 30–40%.
- Once hemoglobin is fully saturated, any additional oxygen (above ~40–50%) dissolves in plasma and provides limited additional benefit to cellular uptake.
In other words, increasing FiO₂ beyond 50% may sound more powerful, but oxygen uptake plateaus and performance returns diminish beyond that threshold.
Wagner et al. (2006) and Richard Bloomer (2009) confirmed that oxygen delivery and VO₂ max do not significantly increase when FiO₂ rises above 50% during exercise. The body simply can’t absorb or use much more oxygen once these physiological limits are reached — making approximately 50% the most efficient and optimized range for EWOT. VO2 Pro’s OptiFlow™ lowers purity under load (beyond 70LPM inspiratory volume) to compensate — lowering the O2 to approx 42% (at 100LPM).